BMW Silent Hektik igniter ignition module CDI TCI Box

BMW Silent Hektik igniter ignition module CDI TCI Box

Buell 1340 (BHP5 US01BB201) igniter ignition module CDI TCI Box

Buell 1340 (BHP5 US01BB201) igniter ignition module CDI TCI Box

Buell 1125 XB ECU ECM CDI black box computer brain (Y0152.1AM)

Beschikbaarheid: Op voorraad
Model
Buell 1125 XB ECU ECM CDI black box computer brain (Y0152.1AM) Research / Repair
SKU
CARU-BU-1125-XB-Y0152-1AM
375,00 € 309,92 €
  •  Dit is een reparatie service voor uw apparaat.
  •  De vermelde prijs is de reparatieprijs.
  •  If we can repair it, this is the price. (Without any additional prices like Quick-Service)
  •  If we are not able to find the fault in the unit, we will only charge research costs,
  •  Met uitzondering van producten die standaard worden gereviseerd.

Kies wat u wilt doen:
 Ophaal Service  Stuur het zelf op



Testing Ignition unit

You pay this amount if your unit has been tested by Carmo.
Testing within 3 working days.
(We also offer a fast service, with delivery by 10:00, ready after 16:00 Mon-Fri)

Test procedure:

All of our tests are performed with a simulation-based protocol; we send the exact same signals to your ECU as those normally provided by your motorcycle. This way we can approach reality to nearly 100%. Testing in this dynamic fashion ensures a much more reliable result compared to static measurements such as measuring resistance values provided by your workshop manual.



What is tested?:
- Variable load on outputs
- Advance ignition curve relative to the rpm
- Power of the spark at variable load
- Charging of the ignitioncoil in TCI systems and peak voltage at CDI Systems
- Operation at different voltages (8V - 15.5 V)
- Temperature dependence
- Idle up to the rpm limiter
- Endurance test, at least 25 minutes (longer on request)
- Vibration
- Water resistance
- Electromagnetic compatibility tests
- If present, tachometer output, Electronic fuel pump output, TPS and vacuum input, standard / neutral safety

If possible, the circuit board will be provided with two layers of professional moisture protective coating after testing.